Jandy PureLink Cell Chlorine Generator Kit For Salt Water 3 Port Cell Assembly Kit P/N: PLC1400

The AquaPure and PureLink Systems use a process known as electrolysis to produce sodium hypochlorite
(liquid chlorine) from a low concentration of salt added to the pool water. Hypochlorite kills bacteria,
oxidizes organic material. and kills algae then reverts back to salt. The system then reuses the salt and the
process starts over again. The systems are comprised of the following components: 

AquaLink RS PureLink Power Center (for PureLink systems) 
The PureLink system is an all-in-one salt water chlorinator control system power center and cell kit for use with AquaLink RS PDA, All Button, Pool Link, or OneTouch controllers. 
The AquaLink RS PureLink power center converts AC power into low voltage DC current which is required by the cell to perform the electrolysis. 
The LCD display on the user interface offers monitoring of chlorine production, cell modes, salinity level, temperature, water flow and diagnostics. 
The chlorine generator electronics inside the power center are connected with the pool circulation pump electrical source so that the electrolytic cell only operates when the pool pump is on. The flow portion of the Flow/Temp/Salinity Sensor is a backup device only. 
Aqua Pure Control Center (for stand alone systems) 
The AquaPure control center converts AC power into low voltage DC current which is required by the cell to perform the electrolysis. 
The LCD display on the user interface offers monitoring of chlorine production, cell modes, salinity level, temperature, water flow and diagnostics. 
The control center is connected with the pool circulation pump electrical source so that the electrolytic cell can only operate when the pool pump is on. An optional pool pump timer can be utilized to help control this lilnction. The flow portion of the Flow/Temp/Salinity Sensor is a backup device only. 
Electrolytic Cell 
The electrolytic cell contains bipolar electrodes which perform the electrolysis and produce chlorine when energized with DC current. Chlorine is generated as pool water containing salt passes through the cell. The chlorine production can be varied by either adjusting the chlorine production level on the power center or by varying the number of hours the unit is on each day. The system automatically cleans the cell�s electrode plates once every 3 hours by reversing the polarity of the electrical current. Whether the system is in forward or reverse, it is still producting chlorine. 
Flow/ Temperature/ Salinity/Sensor 
The How portion ofthe How/temp/salinity sensor detects if there is adequate water flow through the cell. The salinity portion of the flow/temp/salinity sensor detects the level of salt in the pool water. This salt level is displayed in grams per liter (GPL)* on the user interface liquid crystal display (LCD) whenever the salinity button is pressed. This eliminates the need to manually test the salinity ofthe pool water. The pool temperature is displayed by pressing the Temperature button. 
*l gram per liter (GPL) = 1000 ppm (parts per million)